Registration for a live webinar on 'Precision medicine treatment for anticancer drug resistance' is now open.
See webinar detailsWe noted you are experiencing viewing problems
-
Check with your IT department that JWPlatform, JWPlayer and Amazon AWS & CloudFront are not being blocked by your network. The relevant domains are *.jwplatform.com, *.jwpsrv.com, *.jwpcdn.com, jwpltx.com, jwpsrv.a.ssl.fastly.net, *.amazonaws.com and *.cloudfront.net. The relevant ports are 80 and 443.
-
Check the following talk links to see which ones work correctly:
Auto Mode
HTTP Progressive Download Send us your results from the above test links at access@hstalks.com and we will contact you with further advice on troubleshooting your viewing problems. -
No luck yet? More tips for troubleshooting viewing issues
-
Contact HST Support access@hstalks.com
-
Please review our troubleshooting guide for tips and advice on resolving your viewing problems.
-
For additional help, please don't hesitate to contact HST support access@hstalks.com
We hope you have enjoyed this limited-length demo
This is a limited length demo talk; you may
login or
review methods of
obtaining more access.
Printable Handouts
Navigable Slide Index
- Introduction
- Single-cell assays
- Intracytoplasmic cytokine staining of cells
- Single-cell multiplexed cytokine secretion assay
- ELISPOT
- Immunohistochemistry (IHC)
- Protein expression or cytokine transcripts?
- Which cytokine assay to choose?
- Immunoassays or bioassays?
- Data analysis in cytokine assays
- Generation of the standard curve
- Pitfalls of cytokine assays
- QC/QA issues: general principles
- Assays for IL-12p70 production by human DCs
- Cytokines in clinical trials
- Managing the COVID-19 cytokine storm
- Thank you for your attention
Topics Covered
- Types of cytokine assays available
- Examples of most widely used cytokine assays
- Principles of ELISA and ELISPOT
- How to select the right cytokine assay
- Multiplex analyses and cytokine profiling
- Principles of QA/QC for cytokine assays
- Data analysis and pitfalls
Talk Citation
Whiteside, T. (2022, January 31). Assays for cytokines and cytokine assay performance 2 [Video file]. In The Biomedical & Life Sciences Collection, Henry Stewart Talks. Retrieved December 26, 2024, from https://doi.org/10.69645/YROO9337.Export Citation (RIS)
Publication History
Financial Disclosures
- Prof. Theresa Whiteside has not informed HSTalks of any commercial/financial relationship that it is appropriate to disclose.
Assays for cytokines and cytokine assay performance 2
Published on January 31, 2022
39 min
A selection of talks on Immunology
Transcript
Please wait while the transcript is being prepared...
0:03
Now, we are moving from multiplex type assays to single-cell assays.
We can look here for intracellular cytokine expression
or for the expression of cytokines that are sitting on the surface of cells.
Here, we are looking at human T lymphocytes which are briefly incubated
with an antigen or peptide or activating agents, such as PMA or ionomycin.
If they are permeabilized
and co-incubated with label antibody, fluorescence-labeled antibody,
which is specific for cytokine one, for example and
another antibody specific for cytokine number 2,
which is labeled with Phycoerythrin.
Nuclei are stained with a reagent called DAPI,
shown here in blue and immunofluorescence images,
which can be acquired in an immunofluorescence microscope or by flow cytometry.
What you then see in the images shows the expression of cytokine 1 and
cytokine 2 in the same cells.
Then, you can merge the microscope images and
this confirms co-expression of both cytokines in
the same cell because here the red and the green give you a yellow color and you
can clearly see that the same cytokine RB present are being made in the same cells.
These similar single-cell assays can actually be done without permeabilization of cells
because you can add detection.
Antibody to cells and
if the cytokine is sitting on the surface of the cell,
or if it's sitting bound to the receptor that is present on the surface of the cell,
your detection-labeled antibody will detect the cytokine sitting on a surface,
and that doesn't require permeabilization of the cells.